Msd 8350 Ford 351C-460 Ready-To-Run Pro-Billet Distrib Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pour la voiture Msd 8350 Ford 351C-460 Ready-To-Run Pro-Billet Distrib. MSD 8350 Ford 351C-460 Ready-To-Run Pro-Billet Distributor Installation User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
MSD Pro-Billet Small Diameter
Ready-to-Run Ford V8 Distributor
PN 8350; 351C-460, PN 8354; 351W
PN 8352; 289/302
ONLINE PRODUCT REGISTRATION: Register your MSD product online and you’ll be entered
in our monthly 8.5mm Super Conductor Spark Plug Wire give-away! Registering your product
will help if there is ever a warranty issue with your product and helps the MSD R&D team create
new products that you ask for! Go to www.msdperformance.com/registration.
Important: Read these instructions before attempting the installation.
Parts Included:
1 - Pro-Billet Distributor
1 - Rotor, PN 8467
1 - Distributor Cap, PN 8431
1 - Advance Kit
Note:The terminals of the Ready-to-Run Ford Distributors require spark plug style terminals. You may 
need to changethe terminalsand bootsofyourwires.MSDofferstwokits, PN 8849 or PN 8848 that 
are supplied with nine boots and terminals.
TIMING FUNCTIONS
Before continuing with the installation, here are a few definitions you should be aware of:
Initial Timing: This is  the  base  timing  (also  referred  to  as  idle  timing)  of  the  engine  before  the 
centrifugal advance begins.
Centrifugal Advance:  The centrifugal (or mechanical) advance mechanism is made up of weights, 
springs, advance cams, and an advance stop bushing. The amount and rate of advance that your 
distributor is capable of is determined by the centrifugal timing. If  you  ever  wish  to  lock  out the 
centrifugal advance, refer to the centrifugal advance section. 
Total Timing:This is the total of theinitialtiming plusthe centrifugal advance added together. Example: 
10°  Initial + 25° centrifugal  =  35°  Total  Timing.  (When checking Total timing,  disconnect and cap 
the vacuum canister and plug the vacuum line.)
Vacuum Advance: The  vacuum  advance  will  advance  the timing  up to 10° during partial throttle 
driving (with 15 lbs of vacuum). The vacuum line should be routed to a ported vacuum outlet above 
the throttle plates.
Note:MSD Distributors are supplied with the heavy (slow) advance springs and the 21° stop bushing 
installed. This is to prevent detonation in certain applications. Review the information on pages 
2-3 to determine the best advance curve for your application.
RPM LIMIT AND TACHOMETER INFORMATION
Tach Signal:  The Ready-to-Run Distributor featuresaGrayTachOutputwirewhichprovidesaclean signal 
for mosttachometers andevensome aftermarket fuelinjectionsystems. The signal output 
isa 12volt square wave, 20° dutycycle. Thiswire is alsoresponsible for programming the 
built-in rev limiter. 
1 - O-ring Seal
1 - Vacuum Advance Lock-Out Kit
1 - Tube of Gear Lubricant
1 - Wiring Harness
1 - Gray Tach Jumper
M S D W W W . M S D P E R F O R M A N C E . C O M ( 9 1 5 ) 8 5 7 - 5 2 0 0 F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - MSD Pro-Billet Small Diameter

MSD Pro-Billet Small DiameterReady-to-Run Ford V8 DistributorPN 8350; 351C-460, PN 8354; 351WPN 8352; 289/302ONLINE PRODUCT REGISTRATION: Register you

Page 2 - CHOOSING AN ADVANCE CURVE

2 INSTALLATION INSTRUCTIONSM S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7

Page 3 - CENTRIFUGAL ADVANCE CURVE

INSTALLATION INSTRUCTIONS 3M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7

Page 4

4 INSTALLATION INSTRUCTIONSM S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7

Page 5 - INSTALLATION INSTRUCTIONS 5

INSTALLATION INSTRUCTIONS 5M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7

Page 6 - INSTALLING THE DISTRIBUTOR

6 INSTALLATION INSTRUCTIONSM S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7

Page 7 - BE USED WITH ONE

INSTALLATION INSTRUCTIONS 7M S D   •   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7

Page 8 - PROGRAMMING THE REV LIMIT

TACHOMETER INFORMATIONThe MSD Ready-to-Run has a Gray wire that provides a 12 volt square wave, 20° duty cycle tachometer signal that will trigger mos

Commentaires sur ces manuels

Pas de commentaire